 Intelligent Energy Monitoring Unit:-

1] IEMU is Intelligent Energy Monitoring Unit. It consists of an Energy Meter & a communication device. CT (Current Transformer), PT (Potential Transformer), GPRS signal (Telecom Network) should be available on site for installing the device. The connection is similar to connecting a meter on the site.

2] The metering unit performs 3-phase/Single phase metering with a default accuracy of Class 1(with an option of Class 0.5/0.2)

  3] The communication unit performs the function of obtaining the power consumption parameters from the metering unit to either a concentrator (ZigBee protocol) or straight to the Internet through a GPRS module 

 Metering Unit Specification:-

Accuracy: Class 1 (Default) IEC 61036, IS 13779 CBIP 88 Class 0.5 and 0.2s  (Optional available at extra cost).

Sensing/Measurement: True RMS, 1 Sec update time, 4 Quadrant Power & Energy

Input voltage: 4 Voltage inputs (VR, VY, VB, VN); Programmable 110 or 415 V LL Nominal(Range 80 - 550 V LL), Primary Programmable up to 999 kV, Burden: 0.2 VA Max. Per phase.

Input current: Current inputs (AR, AY, AB) 50 mA – 6 A (Field programmable 1A or 5A), Primary Programmable up to 99 kA, Overload: 10A max continuous, 50A max for 3 sec, Burden: 0.2 VA Max. Per phase.

Aux-Supply: (Control Power) 80 – 300 V AC, (DC Optional), 40-70 Hz, Burden: 4 VA Max

 Display Type:  10 mm height; Bright red LED display

 Display Resolution: 4 digits for instantaneous; 6 digits for integrated

 CT PT Ratio Max: 2000 MVA Programmable 

Communication:  RS  485  serial  channel  connection,  Industry  standard  Modbus  RTU protocol with RS 232 optional, Baud rate: 2400 bps to 19200 bps. (Preferred 9600 bps), Isolation: 2000 volts AC isolation for 1 minute between communication and other circuits.

 

Communication Unit Specification (GPRS)

Peripheral

Interface Type

Parameter

Description

 

Inputs

 

RS-485

 

Serial data

For communication with energy

metering unit

 

Outputs

 

2 x Digital Outputs

 

ON/OFF

Remote-Control of Switches for

control if required

 

 

Connectivity

 

GSM

GSM

Packets

 

For SMS alerts

 

GPRS

TCP/IP

Packets

For Web

Interface/Configurability

 

 

Indicators

Supply Voltage

LED

For Supply available Indication

Network

Connectivity

 

LED

 

For Network Connectivity

 

 

Memory

 

 

128 kB data Flash

 

 

Serial Data

Data Logging on no

communication for up to 1 day with resolution of 5 mins

Power

Input DC Voltage

9V DC

Power supply

 

Time Stamp

Real Time Clock

(RTC)

Time,

Calendar

For Time Stamping of logged

data

·    GPRS Communication costs covered in AMC

·    1 year free support and warranty